    I think that Will Smith is pussy whipped by his wife and Scientology. I think she uses the church against him, with the threat that they will take his kids away and hide them from him. That’s the only explanation I have for his (slightly delayed) response with Chris Rock, and with Will being ok with his wife grooming their son’s underage friend and later having an open relationship with him on the side.


  • The more I look at it I think it might be a 132kV line on a 400kV tower, with the intention to upgrade it some time in the future. I say this because the insulators aren’t actually the full length of the spacing from the tower, there’s a separator between the tower and the start of the insulator fins. This makes me think they’ve left room for longer 400kV insulators to be installed.

    Saying that though I have no idea, there could have been all sorts of other considerations that led to a configuration like that.


  • TWeaK@lemm.eetopics@lemmy.worldStanding under an electricity pylon
    link
    fedilink
    English
    arrow-up
    5
    ·
    edit-2
    2 months ago

    That pun was totally intended, and I cannot fault you for it.

    I was thinking 132kV, but wasn’t sure if this is Europe where you might find 100kV (although again it varies by country). In the UK, 132kV is the boundary between distribution and transmission. DNO’s (Distribution Network Operators) generally use 11kV, 33kV, 66kV (generally rare but used in some areas eg in North West England) and 132kV, TNO’s (Transmission) use 132kV, 275kV and 400kV. Although, a lot of 275kV substations are built to 400kV spec (eg in Scotland), so that they can upgrade in the future.

    You sometimes get this with power lines, they might install higher voltage insulators then run it at a lower voltage until some time later when the network is upgraded. This spoils the game of guess the voltage/makes it more challenging, and you end up with really weird looking connections between large pylons and small poles.


  • Fun fact: You can estimate the voltage by the length of the insulators. My guess is this is around 100kV (2x 3 phase circuits), around the border of transmission and distribution voltages.

    You can also estimate the capacity by the number of conductors per phase. This has a pair of lines for each phase, so a fair chunk, but not the 3 or 4 conductors you sometimes see (although maybe you mainly see that on higher transmission voltages.


  • I don’t think it’s you being paranoid, however at the same time your husband is perhaps more on the front line of things, so should have a better idea.

    I would say that as a journeyman lineman he’ll be pretty decently qualified and probably wouldn’t have as hard a time finding work abroad. It might be a tough sell with lower salaries on paper, but you often find that the standard of living improves and makes it more than worthwhile.